Anping Yuanqiao Petrochemical Equipment Co., Ltd

Anping Yuanqiao Petrochemical Equipment Co., Ltd

Manufacturer from China
Active Member
3 Years
Home / Products / Vane Pack Mist Eliminator /

Stainless Steel 304 316L Vane Pack Mist Eliminator OEM ODM

Contact Now
Anping Yuanqiao Petrochemical Equipment Co., Ltd
Country/Region:china
Contact Person:MrsAmy
Contact Now

Stainless Steel 304 316L Vane Pack Mist Eliminator OEM ODM

Ask Latest Price
Video Channel
Brand Name :Yuanqiao
Model Number :YQ-99
Certification :ISO9001
Place of Origin :Anping, China
MOQ :1pc
Price :Negociation
Payment Terms :L/C, T/T
Supply Ability :1000 pcs per month
Delivery Time :5-10 days
Packaging Details :Wooden boxes
Product Name :Vane Pack Mist Eliminator
Material :Stainless Steel 304, 316L, Etc.
Vane Type :C Type Without Hook
Pitch Of Van :20mm, 25mm, 30mm, Etc.
Sections :According To Manway
Grids :Slot Frame And Through Rod
Shape :Round, Square, Rectangular
Thickness :170mm-240mm or customized
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

500mm Diameter C Type Vane Pack Mist Eliminator

Vane Pack Mist Eliminator​ brief introduction

In the process of industrial production and industrial waste gas discharge,gas-liquid separation is an important process.

Our Vane Pack Mist Eliminator​ isStable performance, long life,Easy to be cleaned Apart the air and liquid, high efficiency

Vane Pack Mist Eliminator​ Technical Parameter

Items Specific Introduction Unit
Materials of drift eliminator Stainless steel  
Tem Resistance 200℃
Baffle plate thickness Set by Customer Requirements mm
Price Lower Higher Higher RMB
Form Horizontal Type ( Plate Type ), Herringbone Type ( Weir Type ), V Type , Combined Type. etc.  
Area of drift eliminator The inner diameter of the desulfurization tower area or cross-sectional area of flue m2
Flow velocity of air tower Plate Type 3-4m/s,Weir Type 2.5-5.5 m/s m/s
Degree Two degrees degree
Interval and height between baffle plates Designed by different desulphurization craft  
Flushing layers of flushing system Upper and bottom of first-degree drift eliminator, bottom of second-degree drift eliminator; Configurable and topper layer of some drift eliminator be flushed in hand laye

Vane Pack Mist Eliminator​ Application:

Vane pack mist eliminator is widely used in various applications to separate liquid droplets from gas streams, in all applications where a contact between liquid and flowing gas, the vane pack demister can supply a good performance. Additionally, tiny mist droplets can be carried away with the gas.

It is widely used in the foaming system and high liquid viscosity system in refineries, chemicals, petrochemicals, pharmaceuticals, dyes and intermediates, aromatics and other process industries.

Stainless Steel 304 316L Vane Pack Mist Eliminator OEM ODM

Vane Pack Mist Eliminator​ Advantage

This technical specification is applicable to the bidding of absorber demister, including the technical requirements for the functional design, structure, performance, manufacture, installation, supply, commissioning and test of the body and auxiliary equipment system of two-stage high-efficiency flat demister.

We will make it in strict accordance with the drawings provided by the customer and meet the technical requirements on the drawings. Any modification or change to the drawings must be approved by the customer.

All equipment and components provided by the manufacturer are mature and reliable and advanced in technology. After several years of operation, it has been proved to be a fully mature and reliable product.

Vane pack demister work condition

The parameters of flue gas collected by closed coke storage system of delayed coking unit are shown in Table 1; After dust removal and desulfurization, it is discharged from the top of the flue gas tower, and the parameters of the net flue gas are shown in Table 2.

Table 1 Flue gas design parameters (case)

No. Item design parameters Note
1 Flue gas flow rate 31000 m3/h
2 Flue gas temperature normal atmospheric temperature
3 H2O 7.3 Vol%
4 O2 19.4Vol%
5 H2S 50mg/Nm3
6 Dust 20mg/Nm3 Oxygen content 3%, standard state, dry basis

Table 2 Outlet flue gas parameters (case)

No. Item Unit Design condition
1 Flue gas flow rate m3/h 32500
2 Temperature ~40
3 humidity wt% 13.3%
4 H2S mg/Nm3 <25
5 Dust mg/Nm3 <10
Inquiry Cart 0